Construction Will Begin on Infrastructure Improvements
MUD 152 is excited to announce that construction will begin on replacing Ground Storage Tank 1 (GST1) at Kline/Walker Water Plant #1 next to Timber’s Elementary on Lonesome Woods Trail in Atascocita South. This project is part of the ongoing infrastructure improvements announced in July 2022 with the selling of Series 2022 bonds. Construction is expected to be completed by May 2024.
The original Water Plant (now known as Kline/Walker Water Plant #1) and GST1 was built and put into service between 1979-1980. GST1 has been recoated and rehabilitated three times over it’s now (almost) 45-year lifespan. With proper maintenance, we expect that bolted galvanized tanks last around 40-50 years. Through the decades, consecutive MUD 152 boards have chosen to invest in regular and optional preventative maintenance to extend the life of GST1. As a result, the District benefited from the tank’s entire useful life.
The new GST1 will be a concrete tank with an expected life of 50 years. When considering overall costs, including projected maintenance costs through its life cycle, the concrete structure was a better value for taxpayers.
We expect this new tank to serve the residents and businesses in our District for many years to come!
FAQs
Superior Public Water System Designation
You may have noticed new signs in the district highlighting us as a designated Superior Public Water System by the Texas Commission on Environmental Quality. This designation means that MUD 152 exceeds minimum standards in proper oversight, safe and clean water, necessary preparedness and management. To qualify for this designation, the district’s facilities and processes must meet standards outlined in the Texas Administrative Code.
(1) To attain recognition as a “Superior Public Water System”, the following additional requirements must be met:
(A) Physical facilities shall comply with the requirements in these sections.
(B) There shall be a minimum of two licensed operators with additional operators required for larger systems.
(C) The system’s microbiological record for the previous 24 months period shall indicate no violations (frequency, number or maximum contaminant level of the drinking water standards.
(D) The quality of the water shall comply with all primary water quality parameters listed in the drinking water standards.
(E) The chemical quality of the water shall comply with all secondary constituent levels listed in the drinking water standards.
(F) The system’s operation shall comply with applicable state statutes and minimum acceptable operating practices set forth in §290.46 of this title (relating to Minimum Acceptable Operating Practices for Public Drinking Water Systems).
(G) The system’s capacities shall meet or exceed minimum water system capacity requirements set forth in §290.45 of this title (relating to Minimum Water System Capacity Requirements).
(H) The system shall have at least two wells, two raw water pumps or a combination of these with enough capacity to provide average daily consumption with the largest well or pump out of service. This requirement shall also apply to treatment plant pumps necessary for operation in accordance with §290.42 of this title (relating to Water Treatment).
(I) The water system shall be well maintained and the facilities shall present a pleasing appearance to the public.